TESTO 310 II - SMART COMBUSTION ANALYZER WITH PRINTER
The testo 310 II has two measurement cells for O2 and CO, and a temperature sensor integrated into the flue gas probe. The gas sensors measure the exact oxygen and carbon monoxide content as well as the flue gas and ambient temperature. From these data, all relevant measurement parameters such as CO2 value, degree of effectivity and flue gas loss are calculated. In addition, the measuring instrument has its strengths in measurement accuracy, configurable measurement display, parallel measurement options, intuitive operation, sturdy housing, connection option to the testo Smart App
Delivery Scope:
Flue gas analyzer testo 310 II incl. printer and calibration protocol for the measurement of O2, CO, hPa and °C, probe 180 mm with cone, silicon hose for pressure measurement, thermal paper, particle filters 5 off. and case
Temperature - Type K TC | |
Measuring range: | -20 do +400 °C |
Accuracy: | ±1.5 % of mv (> 100 °C) ,
±1 °C (-20 to +100 °C) |
Resolution: | 0,1 °C |
Reaction timee: | < 50 sek. |
Flue gas O₂ | |
Measuring range O₂: | 0 do 21 % obj. |
O₂ measurement accuracy: | ±0,2 % obj. |
Measurement resolution O₂: | 0,1 % obj. |
Reaction time t₉₀: | 30 sek. |
Flue Gas Draft | |
Measuring range (differential pressure - flue gas draft): | -20 do +20 hPa |
Accuracy (differential pressure - flue gas draft): | ±1,5 % mierz.wart. (-20 do -3 hPa i +3 ... +20 hPa) ,
±0,03 hPa (-3 do -0,6 hPa i +0,6 ... +3 hPa) ,
±0,02 hPa (-0,6 do +0,6 hPa) |
Resolution (Differential Pressure - Exhaust Gas Draft): | 0,01 hPa |
Efficiency | |
Measuring range (flue gas degree of effectivity, Eta (calculated)): | 0 to 120 % |
Resolution (flue gas degree of effectivity, Eta (calculated)): | 0,1 % |
Flue gas loss (calculated) | |
Measuring range (flue gas loss): | 0 to 99,9 % |
Resolution (flue gas loss): | 0,1 % |
Pressure measurement | |
Measuring range (pressure measurement): | -40 do +40 hPa |
Accuracy (pressure measurementt): | ±1 % mierz.wart. (remaining measuring range) ,
±0,5 hPa (0 do 50 hPa) |
Resolution (pressure measurement) : | 0,1 hPa |
Flue gas CO (without H₂-compensation) | |
Measuring range (CO measurement (without H₂ compensation): | 0 do 4000 ppm |
Accuracy (CO measurement (without H₂ compensation): | ±5 % mierz.wart. (401 do 2000 ppm) ,
±20 ppm (0 do 400 ppm) ,
±10 % mierz.wart. (2001 do 4000 ppm) |
Resolution (CO measurement (without H₂ compensation)): | 1 ppm |
Response time t₉₀ (CO measurement (without H₂ compensation)): | 60 sek. |
Ambient CO | |
Measuring range (ambient CO measurement (with combustion probe): | 0 do 4000 ppm |
Accuracy (ambient CO measurement (with combustion probe): | ±5 % mierz.wart. (401 do 2000 ppm) ,
±20 ppm (0 do 400 ppm) ,
±10 % mierz.wart. (2001 do 4000 ppm) |
Resolution (ambient CO measurement (with combustion probe): | 1 ppm |
Reaction time: | 60 sek. |
General Specifications | |
Weight: net | Approx. 660 g |
Dimensions: | 203 x 83 x 46 mm |
Ambient temperature: | -5 to +45 °C |
Protection class: | IP40 |
Battery life: | > 8 h (pump on, 20 °C ambient temperature) |
Display function: | 7-line graphic display |
Power supply: | 1500 mAh battery, 5V/2A AC adapter |
Maximum humidity: | 0 to 80 %RH |
System requirements: | requires iOS 13.0 or later; requires Android 8.0 or later; mobile device with Bluetooth 4.0 required |
Radio Range: | 60 m |
Storage temperature : | -20 to +50 °C |
Producent code: | 0563 3107 |
Pictures: | illustrative |